Measurement System of AC Motor Fed by Inverter
Yan Zhi'an, He Zhiming, Gu¡¡Bing
(Xi'an Jiaotong University, Xi'an 710049, China)
![]()
![]()
Abstract: The voltage and current signals for the motor-inverter system
are periodic wide band non-sinusoidal in character.Hence, the conventional AC measurement
device cannot function properly.A new synchronous sampling method based on digital
filtering is developed. It is based on PC,data acquisition board and virtual instrument
software.The loss summation method is used for calculating output power of AC motor.The
desired accuracy is achieved.
Keywords: inverter;AC motor;motor testing;virtual instrument;synchronous
sampling