Application of Particle Image Velocimetry to Measurement of
Poisoeullie Flow and Flow around a Circular Cylinder
Zhang Wei1,Wang
Yuan1,Xu Zhong1,Jin Wen2
(1.School of Energy and Power Engineering,Xi'an Jiaotong University, Xi'an 710049,China;
2.Xi'an Aerotechnical College)
![]()
![]()
Abstract: In order to test the accuracy and resolution of complex vortex
by particle image veloci-metry(PIV),velocity fields of poisoeulie flow and flow around a
circular cylinder were measured. Comparison between the measured velocity profile and
analytical solution of poisoeullie flow shows that good agreement was found within the 90%
measured region, while the former was lower than the latter near the wall because of
velocity polarization. Further measurement of flow around a circular cylinder at Re=500
provided the distribution area of main flow, shear layer flow, recirculated flow and
vortex. The results validate that PIV is well suitable to investigate complex flow
pattern.
Keywords: PIV;poisoeullie flow;measurement accuracy;flow around a
circular cylinder